Objectives: The aim of this study was to identify risk factors for new-onset atrioventricular (AV) block requiring pacemaker (PM) implantation after transcatheter aortic valve implantation (TAVI).
Background: High-grade AV block and consecutive PM implantation are frequent complications following TAVI.
Methods: For logistic regression analysis, we included 159 patients (mean age: 81 +/- 6 years, EuroSCORE: 22 +/- 13%) who underwent TAVI (n = 116 transfemoral, n = 4 via subclavian artery, n = 37 transapical, n = 2 transaortic) between June 2007 and January 2009 and who had no previously implanted PM.
Results: Thirty-five patients (22%) developed new-onset post-operative AV block with the need of PM implantation. Logistic regression revealed a 2-fold increased risk for new-onset AV block in patients in whom a large valve is implanted in a small annulus (32% pacemaker implantations, odds ratio [OR]: 2.378, p = NS), a 4-fold increased risk with the implantation of the CoreValve (Medtronic, Minneapolis, Minnesota) versus the Edwards Sapien valve (Edwards Lifesciences, Irvine, California) (27% pacemaker implantations, OR: 3.781, p = NS), and a 5-fold increased risk for patients who exhibit an AV block episode instantly during the implantation procedure (49% pacemaker implantations, OR: 4.819, p = 0.001). Pre-existing ECG alterations were not identified as risk factors for AV block after transcatheter aortic valve implantation.
Conclusions: We assume that conduction tissue impairment is provoked by mechanical compression with large prostheses in smaller annuli or in the larger area of the CoreValve covering the outflow tract and may appear instantly during the implantation procedure. Continuous post-operative electrocardiogram monitoring should be performed for at least 3 days in all patients after TAVI procedures and until discharge in patients with increased risk for this complication.
Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Risk for permanent pacemaker after transcatheter aortic valve implantation: a comprehensive analysis of the literature.J Cardiovasc Electrophysiol. 2012 Apr;23(4):391-7. doi: 10.1111/j.1540-8167.2011.02211.x. Epub 2011 Nov 3. J Cardiovasc Electrophysiol. 2012. PMID: 22050112 Review.
-
Patients without prolonged QRS after TAVI with CoreValve device do not experience high-degree atrio-ventricular block.Catheter Cardiovasc Interv. 2013 Apr;81(5):882-7. doi: 10.1002/ccd.24657. Epub 2012 Dec 3. Catheter Cardiovasc Interv. 2013. PMID: 22972678
-
Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.JACC Cardiovasc Interv. 2012 May;5(5):540-551. doi: 10.1016/j.jcin.2012.03.004. JACC Cardiovasc Interv. 2012. PMID: 22625193
-
Atrioventricular block after transcatheter balloon expandable aortic valve implantation.JACC Cardiovasc Interv. 2008 Jun;1(3):305-9. doi: 10.1016/j.jcin.2007.12.009. JACC Cardiovasc Interv. 2008. PMID: 19463318
-
Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis.J Am Coll Cardiol. 2014 Jul 15;64(2):129-40. doi: 10.1016/j.jacc.2014.04.033. J Am Coll Cardiol. 2014. PMID: 25011716 Review.
Cited by
-
Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?Turk J Med Sci. 2023 Oct 25;53(6):1799-1806. doi: 10.55730/1300-0144.5750. eCollection 2023. Turk J Med Sci. 2023. PMID: 38813482 Free PMC article.
-
Impact of cancer in patients with aortic stenosis undergoing transcatheter aortic valve replacement: A systematic review and meta-analysis.Int J Cardiol Heart Vasc. 2024 Apr 16;52:101410. doi: 10.1016/j.ijcha.2024.101410. eCollection 2024 Jun. Int J Cardiol Heart Vasc. 2024. PMID: 38650615 Free PMC article.
-
Predictors of permanent pacemaker implantation in aortic valve diseases after TAVI with vitaFlow liberty system.Front Cardiovasc Med. 2023 Sep 29;10:1277528. doi: 10.3389/fcvm.2023.1277528. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37840951 Free PMC article.
-
Risk Factors, Management, and Avoidance of Conduction System Disease after Transcatheter Aortic Valve Replacement.J Clin Med. 2023 Jun 30;12(13):4405. doi: 10.3390/jcm12134405. J Clin Med. 2023. PMID: 37445439 Free PMC article. Review.
-
Prediction of permanent pacemaker implantation after transcatheter aortic valve replacement: The role of machine learning.World J Cardiol. 2023 Mar 26;15(3):95-105. doi: 10.4330/wjc.v15.i3.95. World J Cardiol. 2023. PMID: 37033682 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous